No Image
Available
3/4'' 975Xl2 Reduced Pressure Principle Backflow Preventer With Test Cocks Oriented Face
Image may not reflect selected features
3/4'' 975Xl2 Reduced Pressure Principle Backflow Preventer With Test Cocks Oriented Face (34-975XL2TCU) by Zurn Industries
The 3/4'''' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bronze body test cocks are oriented face up and positioned vertically for easy installation close to a wall. The convenient separate access to the relief valve and each check valve reduces labor costs and repair time. The 975XL2TCU is favored by installers around the world, and is the simplest, best performing, and most reliable backflow preventer in the market today.
Product Specification
Item #
34-975XL2TCU
Dimensions
Additional product details
Vendor Item #
34-975XL2TCU
Plumbing Category
Water Handling
Plumbing Subcategory
Backflow Prevention
Family
xl2
AltImageName1
/ZRN/ZURN_34-975XL2TCU_F.jpg
AltImageName2
/ZRN/ZURN_34-975XL2TCU_L.jpg
AltImagePath1
/ZRN-ZURN_34-975XL2TCU_F.JPEG
AltImagePath2
/ZRN-ZURN_34-975XL2TCU_L.JPEG
Bullet10
Certified to NSF/ANSI 372* by IAPMO R&T
Bullet5
ASSE® Listed 1013
Bullet6
IAPMO® Listed
Bullet7
CSA® Certified
Bullet8
AWWA Compliant C511
Bullet9
Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Country
USA
Description
The 3/4'' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bro
Height
6.3
Install Link
Length
13
Low Lead
Yes
MadeInUSA
Yes
Material
Low Lead Cast Bronze
Minimum Order Quantity
1
Prop65
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
SafetyList
UL, C-UL
Ship Weight
14
Shipping Height
6.25
Shipping Length
13
Shipping Width
10
Spec Sheet
UOM
Each
Weight
14
Width
10
Manufactured By
Zurn Industries
Call for Price
Qty:
BASE PRICE:
$
0
00
/ / 1
($0.00 / 1)
Add To Cart
Add To Estimate
Add To Wishlist
Save To Compare
Availability:
  • Manufacturer availability unknown.
More In This Collection From xl2
Item Description
Our most popular backflow preventer model, the 1'''' 975XL2AG Reduced Pressure Principle Backflow Preventer with air gap is utilized on potable water applications for high health hazard protection from backsiphonage and backpressure of contaminated water. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce valuable labor costs and repair time, while the short lay length eases replacement costs. The 975XL2 includes all the necessary components for managing your system, and is the simplest, most reliable backflow preventer in the irrigation market today.

  • Item ID: 4077C7G
  • Width:
  • Height:
  • Extra Data: Easy access to first check simplifies debris removal, Entire unit serviceable in line, Pre-assembled with backflow, pressure regulation, and strainer components, Repair kit allows for a quick fix, instead of a full replacement
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975LXL_1.jpg
  • AltImageName2: /ZRN/ZRN1-975XL2AG_2.jpg
  • AltImageName3: /ZRN/ZRN1-975XL2AG_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975LXL_1.JPEG
  • AltImagePath2: /ZRN-ZRN1-975XL2AG_2.JPEG
  • AltImagePath3: /ZRN-ZRN1-975XL2AG_3.JPEG
  • Bullet10: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
  • Bullet5: Low-lead law compliant
  • Bullet6: ASSE® Listed 1013
  • Bullet7: IAPMO® Listed
  • Bullet8: CSA® Certified B64.4
  • Bullet9: AWWA Compliant C511
  • Country: USA
  • Description: The Zurn Wilkins 975XL2AG Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The wye pattern, bronze body provides separate access to each check valve and the relief valve for servicing.
  • Height: 6.3
  • Install Link: Installation Link
  • Length: 13
  • Low Lead: Yes
  • MadeInUSA: Yes
  • Material: Low Lead Cast Bronze
  • Minimum Order Quantity: 1
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • SafetyList: UL, C-UL
  • Shipping Height: 6.25
  • Shipping Length: 13
  • Shipping Width: 10
  • Spec Sheet: Spec Sheet
  • UOM: Each
  • Weight: 14
  • Width: 10
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 406V4MM
  • Width:
  • Height:
  • Family: xl2
  • Country: United States
  • Height: 6.9
  • Install Link: Installation Link
  • Length: 23.1
  • Low Lead: Yes
  • MadeInUSA: Yes
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Weight: 39
  • Width: 23.1
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 4077C81
  • Width:
  • Height:
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975LXL_1.jpg
  • AltImageName2: /ZRN/ZRN1-975XL2AG_2.jpg
  • AltImageName3: /ZRN/ZRN1-975XL2AG_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975LXL_1.JPEG
  • AltImagePath2: /ZRN-ZRN1-975XL2AG_2.JPEG
  • AltImagePath3: /ZRN-ZRN1-975XL2AG_3.JPEG
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 407HG86
  • Width:
  • Height:
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975LXL2_1.jpg
  • AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
  • AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975LXL2_1.JPEG
  • AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
  • AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 4077K1M
  • Width:
  • Height:
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975XL2AG_1.jpg
  • AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
  • AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975XL2AG_1.JPEG
  • AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
  • AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
  • Install Link: Installation Link
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description
Our most popular backflow preventer model, the 3/4'''' 975XL2AG Reduced Pressure Principle Backflow Preventer with air gap is utilized on potable water applications for high health hazard protection from backsiphonage and backpressure of contaminated water. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce valuable labor costs and repair time, while the short lay length eases replacement costs. The 975XL2 includes all the necessary components for managing your system, and is the simplest, most reliable backflow preventer in the irrigation market today.

  • Item ID: 407HG7M
  • Width:
  • Height:
  • Extra Data: Easy access to first check simplifies debris removal, Entire unit serviceable in line, Pre-assembled with backflow, pressure regulation, and strainer components, Repair kit allows for a quick fix, instead of a full replacement
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975LXL2_1.jpg
  • AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
  • AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975LXL2_1.JPEG
  • AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
  • AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
  • Bullet10: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
  • Bullet5: Low-lead law compliant
  • Bullet6: ASSE® Listed 1013
  • Bullet7: IAPMO® Listed
  • Bullet8: CSA® Certified B64.4
  • Bullet9: AWWA Compliant C511
  • Country: USA
  • Description: The Zurn Wilkins 975XL2 Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The wye pattern, bronze body provides separate access to each check valve and the relief valve for servicing.
  • Height: 6.3
  • Install Link: Installation Link
  • Length: 13
  • Low Lead: Yes
  • MadeInUSA: Yes
  • Material: Low Lead Cast Bronze
  • Minimum Order Quantity: 1
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • SafetyList: UL, C-UL
  • Shipping Height: 6.25
  • Shipping Length: 13
  • Shipping Width: 10
  • Spec Sheet: Spec Sheet
  • UOM: Each
  • Weight: 13
  • Width: 10
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 407AKPU
  • Width:
  • Height:
  • Family: xl2
  • AltImageName1: /ZRN/ZRN112-975LXL2_1.jpg
  • AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
  • AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
  • AltImagePath1: /ZRN-ZRN112-975LXL2_1.JPEG
  • AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
  • AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
  • Install Link: Installation Link
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Parts
Item Description


  • Item ID: 407AEWK
  • Width:
  • Height:
  • Family: xl2
  • Install Link: Installation Link
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Parts
Item Description


  • Item ID: 407AEWW
  • Width:
  • Height:
  • Family: xl2
  • Install Link: Installation Link
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
Item Description


  • Item ID: 407AGU8
  • Width:
  • Height:
  • Family: xl2
  • Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Spec Sheet: Spec Sheet
  • Standard Plumbing Category: Water Handling
  • Standard Plumbing Subcategory: Backflow Prevention
To: From: Subject: