Item Description
The 350DA Double Check Detector Backflow Assembly protects against backsiphonage and backpressure in low health hazard, fire protection applications. Featuring a metered bypass system, the 350DA efficiently and effectively detects leaks and any unauthorized water use, saving you added costs associated with maintenance and repairs. The Zurn Wilkins Compound Check provides low headloss, and backflow installation is approved in both horizontal and vertical positions.
Item ID: 407AGRL
Width:
Height:
Extra Data: Horizontal or vertical installation offers versatility and eases installation, Leak and unauthorized water use detection decreases risk of damage and unnecessary costs, Lowest lifecycle costs in the Backflow industry, Patented Compound Check offers reliable performance and improved flow characteristics
Family: da
Bullet5: ASSE® Listed 1048
Bullet6: CSA® Certified B64.5
Bullet7: AWWA Compliant C510
Bullet8: UL® Classified
Country: USA
Height: 60.6
Length: 75.4
Low Lead: Yes
Minimum Order Quantity: 1
Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Extra Data: Horizontal or vertical installation offers versatility and eases installation, Leak and unauthorized water use detection decreases risk of damage and unnecessary costs, Lowest lifecycle costs in the Backflow industry, Patented Compound Check offers reliable performance and improved flow characteristics
Family: da
Bullet10: FM Approved
Bullet5: ASSE Listed 1048
Bullet6: CSA Certified B64.5
Bullet7: AWWA Compliant C510
Bullet8: UL Classified
Bullet9: C-UL Classified
Description: The 8'' 350DAOSYPI Double Check Detector Backflow Assembly, with flanged end OSandY gate valve and Post Indicator gate valve, protects against back siphonage and backpressure in low health hazard, fire protection applications. Featuring a metered b
Description: The 6'' 475DABG Reduced Pressure Detector Backflow Assembly, with grooved end butterfly valves with integral supervisory switches, is utilized in high hazard, fire protection applications to protect against both back siphonage and backpressure. The
Extra Data: Epoxy-coated ductile iron body and stainless steel internals resist corrosion, Leak and unauthorized water use detection decreases costs over time, Protection from contaminated water in high hazard fire protection applications, Relief valve and checks are easily accessible for in-line maintenance
Family: da
Bullet10: FM Approved
Bullet5: Lowest lifecycle costs
Bullet6: ASSE Listed
Bullet7: UL Classified
Bullet8: AWWA Compliant
Bullet9: C-UL Classified
Description: The 6'' 375DAG Reduced Pressure Principle Detector Backflow Assembly, with grooved end OSandY gate valves, protects against backsiphonage and backpressure of contaminated water in high hazard, fire protection applications. The 375DA features a mete
Extra Data: Horizontal or vertical installation offers versatility and eases installation, Leak and unauthorized water use detection decreases risk of damage and unnecessary costs, Lowest lifecycle costs in the Backflow industry, Patented Compound Check offers reliable performance and improved flow characteristics
Family: da
Bullet10: FM Approved
Bullet5: ASSE Listed 1048
Bullet6: CSA Certified B64.5
Bullet7: AWWA Compliant C510
Bullet8: UL Classified
Bullet9: C-UL Classified
Description: The 6'' 350DACFM Double Check Detector Backflow Assembly, with OSandY gate valves and cubic feet meter, protects against back siphonage and backpressure in low health hazard, fire protection applications. Featuring a metered bypass system, the 350D